Sign In | Join Free | My himfr.com
Home > Thermal Cutoff Fuse >

CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

    Buy cheap CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch from wholesalers
     
    Buy cheap CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch from wholesalers
    • Buy cheap CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch from wholesalers
    • Buy cheap CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch from wholesalers

    CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

    Ask Lasest Price
    Model Number : CSRY01
    Brand Name : DESHENG
    Certification : CCC
    Delivery Time : 10-15 days on order date
    Payment Terms : T/T L/C D/P
    Supply Ability : 300,000pcs per month
    • Product Details
    • Company Profile

    CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

    Hydraulic Mechanical Capillary Temperature Controlled Thermostat For Boiler And Oven


    Electro mechanical temperature controls with capillary phial
    Rathgeber's capillary tube thermostats are used all over the world to control and limit temperatures (temperature range from -30°C to +400°C)
    Rathgeber's products are manufactured professionally in accordance with latest technology and in compliance with the appropriate standard DIN EN 60730.
    They operate safely and reliably, provided that specification required is clear at the start of the project.
    Rathgeber supply temperature controls, sensors and limiters with phial and with capillary tube length according to customer specification for applications such as:

    • Boilers
    • Night storage heaters
    • Heat exchangers
    • Water heaters
    • Laboratory equipment
    • Ovens of domestic cookers
    • Washing machines
    • Dishwashers
    • Deep fat fryers
    • High pressure jet washers



    Principle of operation
    The pressurised system which operates according to the principle of expansion of liquid is the heart of a hydraulic thermostat.
    It comprises phial, capillary tube and diaphragm.
    Following an increase in temperature at the phial, the liquid expands in the capillary tube, causing the diaphragm to move. This movement activates a snap-action switch, causing opening or closing of switch contacts.
    It is clear that a high degree of precision is required in manufacture, as a change in temperature of 1°K can cause a movement of the diaphragm between 0,002mm - 0,01mm.
    It is therefore absolutely essential that the phial and capillary tube should not be squashed or otherwise damaged!
    The thermostats are calibrated at room temperature 20°C. If during operation the capillary tube and diaphragm are subjected to a higher temperature the switching point will be changed. If the ambient temperature (TU) is known in advance this can be taken into account during the calibration process. Alternatively it is possible to compensate for the influence of ambient temperature upon the liquid at the diaphragm by fitting a bi-metal device.

    Normally close, open on temperature rise, automatic reset, Earth Terminal Option

    Working voltage and current

    16 Amps @ 250 Vac and 16 Amps @ 400 Vac

    Ø Phial diameter

    3/6 mm

    Cycles life

    100,000 cycles

    Open temperature

    -35°C to 350°C

    Temperature Tolerance

    ±3°C, ±4°C, ±5°C, ±8°C, ±10°C, ±12°C

    Differential Temperature

    depending on open temperature

    Contact resistance

    ≤100 m

    Capillary length

    300~ 3000 mm; other lengths available upon request

    Body temperature

    T120 / T150

    Faston Terminal Connections

    6,3x0,8 mm DIN46244

    Contact Closure Resistance:

    ≤50mΩ

    Insulation Resistance

    ≥100MΩ

    Speed of response

    1.0℃/min

    .Min. electric current

    200mA


    Typical
    Model

    Operating temperature

    Switch

    Voltage
    (V)

    Current
    (A)

    Maximum
    Temperature
    Sensing part(℃)

    H

    L

    OFF(℃)

    DIFF(K)

    OFF(℃)

    DIFF(K)

    WY35A-Ⅰ

    35±4

    5±3

    -35±4

    5±3

    400/250

    16

    70

    WY75A-Ⅰ

    75±3

    5±3

    25±5

    5±3

    CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch

    400/250

    16

    110

    WY110A-Ⅰ

    110±4

    6±4

    60±8

    6±3

    400/250

    16

    120

    WY190A-Ⅰ

    190±8

    8±4

    50±8

    8±4

    400/250

    16

    160

    WY250B-Ⅰ

    250±10

    10±5

    120±12

    10±5

    400/250

    16

    250

    WY350A-Ⅰ

    340±12

    12±6

    60±15

    12±6

    400/250

    16

    400



    Applications:

    ■ - 10 / +16 Refrigeration
    ■ -35 / +35 Fridge
    ■ 0 / 40 Ambient
    ■ 0 / 85 Boliers / Water heaters
    ■ 0 / 93 Dishwashers
    ■ 30 / 110 Bain Marie
    ■ 60 / 200 Deep-fryer
    ■ 50 / 250 Oven
    ■ 50 / 300 Oven
    ■ Other ranges upon request


    Competitive Advantage:

    1. VDE CE CQC Approved.

    2. A variety of coating configuration and shell materials are available according to different usages

    3. RoHs (2002/95/EC Directive) compliant

    4. Customized adjuster rod lengths and requirements are accepted

    5. To supply adjustable knob, bezel and mounting screws

    6. Adjustable temperature with positive contact separation

    7. Mounting bushings/fittings and various sealing bushings are available

    8. SPST or SPDT contact configuration

    9. Durable stainless steel or copper construction












































    Quality CSRY 250V 10A Thermal Cutoff Fuse , Non-Recloseable Thermal Fuse Switch for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Jiangsu ChangSheng Electric Appliance Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)